Versions:
- BIOS: 01.01.0005
- ME: 03.00.07.114
- BMC: 01.10.7004
- FRUSDR: 1.03
Fixes in BIOS R01.01.0005:
- SEL intermittently reports therm trip
Known Issues in ME 03.00.07.114:
- If host main power delayed relatively to the standby power for 720-770ms ME stop .
- Unable to set Alert Threshold Limit to 0 degrees (minimum from capabilities) for Inlet Temperature Trigger Type Policy.
- [MESDC] Compliance Test 7.8 Set PSU Configuration w/Power Cycle is failed.
- [MESDC] ME FW Status in S3 State is failed.
- During Host Warm Reset flow, unexpected Intel? SPS 3.0 E5 Firmware exception may be promoted to Platform Global Reset.
- When auto configuration is performed and efficiency readings are provided from BMC, ME keeps requesting PSUs for readings.
- Permanent Node Busy completion code received when trying to ColdReset ME after setting new value of SlopeComp and Offset coefficients.
- NM constantly forces RAPL limit 2 to 0 Watt after a series of SMBAlerts.
- NM policy power range for memory domain is changed to incorrect values after NM PTU characterization is run.
Fixes in BMC 01.10.7004:
- Do not log extra failures on CATERR
Fixes in FRUSDR 1.03:
- Fixed a problem with System Airflow record in R2224 and R2312 chassis.
- BMC shows sensor for PS2, IO module, and SAS module when they are not present