Mellanox MHGA28-XTC rev.A2 HCA Card Firmware

Software Screenshot:
Mellanox MHGA28-XTC rev.A2 HCA Card Firmware
Software Details:
Version: 5.3.000
Upload Date: 30 May 15
Developer: Mellanox
Distribution Type: Freeware
Downloads: 20
Size: 343 Kb

Rating: nan/5 (Total Votes: 0)

New Features:

- Active cable support

Added the following debug features:

- The new .ini parameter absorb_ecc_unrecoverable can be used to configure the HCA to treat DIMM unrecoverable errors as recoverable
- The new .ini parameter gpio_num_indicates_fsr_en can be used to set a specific GPIO to indicate whether Fast Self-Refresh mode is enabled or disabled. See the command ENABLE_LAM in the PRM.

Bug Fixes:

- Doorbell loss upon UAR page size >= 64KB
- A false Fatal Error is reported upon a WQE fetch translation error
- May cause an internal error upon closing QPs in a condition of RNR stress
- Performance may be degraded upon receiving a multicast packet that is not a member of any multicast group
- MTT corruption
- Under very stressful conditions, multiple receive CQEs may be generated
- It is possible to re-enable a port using a MAD after disabling it with the command ModStatConfig
- NodeInfo returns the wrong Revision (device revision) value for a DDR device
- A Send CQE with error is generated only if the QP was in RTS prior to moving to the Error state
- The command QUERY_FW fails after running the RUN_FW command
- The HCA might exceed the maximum trap generation rate upon processing different trap types
- Suspend_QP command timeout