DC Arc Flash Analytic

Software Screenshot:
DC Arc Flash Analytic
Software Details:
Version: 3.0.1
Upload Date: 6 Feb 16
Developer: ARCAD
Distribution Type: Shareware
Price: 250.00 $
Downloads: 14
Size: 2885 Kb

Rating: nan/5 (Total Votes: 0)

DC-Arc-Flash-Analytic version 3.0 (DCAFA V3.0) software simplifies determining incident energy at working distance, arc flash, limited and restricted approach boundaries in DC power systems when work is to be performed on or near the energized equipment. The program performs the analysis by taking into account power system voltage, available short circuit current, circuit time constant, equipment configuration, working distance and protective device time-current characteristics. DCAFA V3.0 will also assist you in selection of proper Personal Protective Equipment (PPE) and creation of arc flash & shock hazard warning labels. The program is applicable for systems with voltages from 180 to 15,000V DC, short circuit fault currents from 400A to 50kA, circuit time constants from 0 to 50msec, conductor gaps from 1 to 6 inches.

Arcing current can be expressed as a function of the length of the gap and arcing voltage. Arcing voltage can be derived as a function of arcing current, system voltage and the available fault current. DCAFA V3.0 calculates arcing current using the iterative method by cycling through the equations for arcing current and arcing voltage until the answers converge. Next, the program will determine arc duration based on protective device time-current characteristics and circuit time-constant. Lastly, the program will calculate incident energy at working distance, arc flash and shock protection boundaries.

DCAFA V3.0 comes complete with a built-in library of selected protection devices and the capability to extend the library. The program will determine arc duration based on predicted arcing current value, circuit time constant and selected protection device type and rating. While circuit time constant affects current rise and protective device performing characteristics, it will also have an impact on arc duration. Therefore, time current characteristic of the upstream protective device clearing the fault has to be adjusted for the time constant. If this occurs, the process of determining the protective device operating time is cumbersome. DCAFA V3.0 will cycle through relationships between the effective RMS current, available fault current, number of time constants, analytical expression for the selected protective device time-current characteristic and make proper adjustments to arc duration.

Requirements:

.NET Framework 3.5

Limitations:

Limited functionality

Screenshots

dc-arc-flash-analytic_1_290410.jpg

Supported Operation Systems

Similar Software

Resistor Values
Resistor Values

24 Sep 15

Magrathea
Magrathea

13 Apr 18

GeCCO
GeCCO

23 Jan 15

Idea Rover
Idea Rover

16 Apr 15

Other Software of Developer ARCAD

Comments to DC Arc Flash Analytic

Comments not found
Add Comment
Turn on images!